index

What Is TDS in Water and What Level Is Safe for Drinking, Cooking and Industrial Use?

kaveri Water Purifier

Water Quality Basics · India

What Is TDS in Water and What Level Is Safe for Drinking, Cooking and Industrial Use?

You have seen the number on a TDS meter. But what does it mean, and when should you worry? Here is the full answer in simple words, with the limits that matter in India.

500 ppmBIS acceptable limit for drinking water
2,000 ppmPermissible only if no better source exists
Under 300WHO rates this as excellent taste

By Kaveri RO  ·  Jaipur  ·  ~14 min read

Open any RO shop, any water purifier ad, or any family WhatsApp group in India, and someone is talking about TDS. "My water is 800 TDS, is that bad?" "The RO gives 20 TDS, is that too low?" Most people have a number but no idea what it means. This guide explains TDS from the start. You will learn what it is, what number is safe for drinking, cooking and factory use, how to test it, and what to do when it is too high or too low.

The Short Answer

TDS means Total Dissolved Solids. It is the total amount of minerals and salts dissolved in water, measured in ppm (parts per million) or mg/L. In India, BIS says drinking water should have TDS up to 500 ppm. Up to 2,000 ppm is allowed only when no better source is available. For the best taste, aim for 50 to 300 ppm. Cooking and bathing water can be a little higher. Factories need very different levels: boilers and medicine plants need near zero, while cooling towers can use more.

In This Guide

01What TDS means, in simple words
02The TDS scale: what each number means
03Safe TDS for drinking water
04TDS for cooking, bathing and plants
05TDS for factories and industry
06What TDS does not tell you
07How to test and reduce TDS
0814 common questions answered
Section 01

What Is TDS in Water? A Simple Explanation

Water is never just water. As it flows over rocks and soil, or through pipes, it picks up tiny bits of minerals and salts and carries them along. These bits are so small that you cannot see them. They dissolve, like sugar in tea. Together, all of these dissolved things are called Total Dissolved Solids, or TDS.

What Is Inside TDS?

Most of it is harmless minerals like calcium, magnesium, sodium, potassium, chloride, sulphate and bicarbonate. Some of it can be harmful, like nitrate, fluoride, arsenic or heavy metals. TDS adds all of them up and gives you one number. It does not tell you which ones are there.

How Is TDS Measured?

TDS is measured in ppm (parts per million) or mg/L (milligrams per litre). These two mean the same thing. If a sample has 500 ppm TDS, it holds 500 milligrams of dissolved solids in every litre of water. A handheld TDS meter does not count the solids directly. It checks how well the water carries electricity, called conductivity, and then multiplies by a factor (usually between 0.5 and 0.7) to show TDS.

Where Does TDS Come From?

⛰️

Natural sources

Rocks, soil and underground layers. This is why borewell water in dry areas like Rajasthan often has high TDS, sometimes above 1,000 ppm.

🏭

Human sources

Factory waste, sewage, farm fertiliser and cleaning chemicals can all add dissolved solids to water.

🚰

Pipes and tanks

Old or rusty pipes can add metals. Salt-based water softeners can slightly raise TDS because they swap one salt for another.


Section 02

The TDS Scale: What Each Number Means for Drinking Water

Here is an easy scale to read your TDS number. It combines the BIS limits used in India with the WHO taste guide.


Under 50
Very low

Flat taste. Very few minerals left.


50 to 300
Excellent

Fresh taste with healthy minerals.


300 to 500
Good

Safe by BIS. Taste is fine for most people.


500 to 900
Above limit

Over the BIS acceptable limit. Salty or bitter taste starts.


900 to 2,000
Poor

BIS allows only if no other source. Treat it.


Over 2,000
Not fit

Do not drink without treatment.

Why does this scale say 500 and not 600? The WHO taste guide calls water up to 600 ppm "good". But India follows the BIS standard IS 10500, which sets the acceptable limit at 500 ppm. In India, use 500 as your line.

The WHO has not set a health-based limit for TDS. It uses TDS as a taste guide. The WHO taste bands are: under 300 excellent, 300 to 600 good, 600 to 900 fair, 900 to 1,200 poor, and above 1,200 unacceptable.


Section 03

What TDS Level Is Safe for Drinking Water in India?

The BIS Rule (IS 10500:2012)

The Bureau of Indian Standards gives two numbers for every water quality item. The first is the acceptable limit. The second is the permissible limit in the absence of an alternate source. For TDS, these are:

Item Acceptable limit Permissible limit (no other source)
Total dissolved solids (TDS) 500 mg/L
Total hardness (as CaCO3) 200 mg/L
Chloride 250 mg/L
Sulphate 200 mg/L
BIS notes that above 500 mg/L, taste gets worse and it may irritate the stomach. The aim is always to meet the acceptable limit.

The Best TDS for Daily Drinking

If you want a simple target, 50 to 300 ppm tastes best and still has useful minerals like calcium and magnesium. Anything up to 500 ppm is fine under BIS. Water above 500 ppm is not always dangerous, but the taste often turns salty or bitter, and it is not what BIS calls acceptable.

What About Bottled Water?

Packaged drinking water must follow IS 14543, and its TDS limit is a maximum of 500 mg/L. Natural mineral water is different. FSSAI guidance gives a TDS range of 150 to 700 mg/L for it, because the minerals come from the source. Standards can be revised, so check the latest version if you run a plant.

Important: A good TDS number does not mean the water is safe. Water with 150 ppm TDS can still carry bacteria, arsenic or fluoride. And water with 800 ppm TDS made of harmless minerals can be safe to drink. TDS is a first check, not the full answer. Always do a full lab test if you are unsure.

Not sure what is in your water? Get it tested and get a clear treatment plan. Talk to Kaveri RO

Section 04

Safe TDS Levels for Cooking, Bathing, Plants and Home Use

Drinking water needs the strictest limit because you take it into your body every day. Other home uses can handle more. Here is a simple guide.

Use Good TDS range What happens if it is too high
Drinking 50 to 300 ppm (up to 500 is acceptable) Salty or bitter taste. BIS says it may upset the stomach.
Cooking (dal, rice, tea) Under 500 ppm Hard water can make dal and rajma take longer to cook, and tea may look cloudy or leave a film.
Bathing and washing Under 1,000 ppm is workable Soap lathers less, clothes feel stiff, and white scale builds on taps, tiles and geysers.
Geyser and washing machine As low as you can manage, and soft Scale shortens the life of heating parts and wastes electricity.
Garden plants and lawns Salt builds up in the soil and burns leaf tips. Sensitive plants suffer first.
Toilet flushing, floor cleaning No big problem, apart from scale marks.
These are practical guides, not legal limits. Hardness matters as much as TDS for cooking, bathing and appliances.

Is Very Low TDS Water Bad?

Many families with RO purifiers see a reading of 10 to 30 ppm. That water has almost no minerals. It is clean, but it can taste flat. Some experts and the WHO advise that people who drink only demineralised water should get calcium and magnesium from food or through a mineral cartridge. A healthy diet gives most of your minerals, so low TDS is not an emergency. But it is a good reason not to run an RO on water that is already low in TDS.


Section 05

What TDS Level Is Right for Industrial Use?

In industry, the right TDS depends on what the water does. Some jobs need water that is almost pure. Others can use water that would be undrinkable. Using the wrong water is expensive, so this is where TDS control saves real money.

Industrial use Typical target Why it matters
Boiler feed water (low pressure) Very low, with hardness near zero Hardness makes scale on boiler tubes, which wastes fuel and can burst tubes. Boiler water inside a low pressure boiler is usually kept below about 3,500 ppm by blowdown.
High pressure boilers and turbines DM water, close to 0 ppm Even tiny salts cause deposits and damage at high temperature. Always follow your boiler maker.
Cooling tower makeup Often 400 to 1,000 ppm workable Water is reused many times and gets saltier. If you allow 2,000 to 3,000 ppm in the loop and run 3 to 5 cycles, makeup of 400 to 1,000 ppm works.
Food and beverage Usually under 500 ppm, many aim lower Taste, colour and product shelf life depend on clean, soft water. Follow your product specification.
Medicine and lab water Below 1 ppm (conductivity near 1.3 µS/cm or less) Purity rules are very strict. Needs RO plus further polishing.
DEF (AdBlue) making Conductivity under 0.5 µS/cm Any extra salt can damage vehicle emission systems. RO alone is not enough.
Cleaning and dust control Almost any level Water quality matters little. RO reject water often works well here.
These are general guides. Your equipment maker, product standard or regulator sets the final limit.

The cooling tower sum, step by step: If your tower allows 2,000 ppm in the circulating water and you run it at 4 cycles of concentration, then makeup water can be about 2,000 ÷ 4 = 500 ppm. That is why high TDS borewell water often needs RO or softening before it goes to a cooling tower.


Section 06

What TDS Does Not Tell You

Many people trust the TDS meter too much. It is a handy tool, but it has limits.

🦠

Germs

TDS cannot show bacteria, viruses or other germs. Water with perfect TDS can still make you sick.

☠️

Harmful metals

Arsenic and lead are harmful at tiny amounts. The BIS limit for both is just 0.01 mg/L, far too small to change TDS much.

🦷

Fluoride and nitrate

Fluoride (BIS acceptable limit 1.0 mg/L) and nitrate (45 mg/L) can be above the limit while TDS looks normal.

🧂

Which minerals

Calcium and magnesium are healthy. Too much sodium or sulphate is not. TDS adds them all into one number.

TDS and Hardness Are Not the Same

Hardness counts only calcium and magnesium. TDS counts everything dissolved. A water sample can have high TDS but moderate hardness, or the other way round. BIS sets hardness at 200 mg/L acceptable and 600 mg/L permissible. If you have scale on taps and geysers, hardness is the real problem, and a softener helps more than an RO.


Section 07

How to Check TDS and How to Reduce It

Test TDS at Home in 5 Steps

1

Use a clean glass

Rinse a glass with the water you want to test. Soap or old water in the glass will give a wrong reading.

2

Fill and dip the meter

Fill the glass. Switch on the meter and dip the tip up to the marked line. Do not dip the whole meter.

3

Wait and tap

Tap gently to remove air bubbles. Wait about 10 seconds until the number stops changing.

4

Note the number

Write it down. Test again at a different time. Borewell and tanker water can change from day to day.

5

Confirm with a lab if it matters

Cheap meters can be off by 10% or more. For a plant, business or health worry, get a NABL lab test. It costs about ₹3,000 to ₹8,000 and checks far more than TDS.

What Reduces TDS and What Does Not

Method Reduces TDS? Good to know
Reverse osmosis (RO) Yes, by about 90% to 99% Best for high TDS. Wastes some water as reject, which can be reused for cleaning and gardens.
DM plant (ion exchange) Yes, to near zero Used in boilers, labs and DEF plants. Needs acid and alkali for regeneration.
Distillation Yes Very pure water, but slow and uses a lot of energy.
Water softener No Removes hardness only. Swaps it for sodium, so TDS stays about the same.
Boiling No Kills germs, but as water evaporates, TDS actually goes up.
UV purifier No Kills germs only.
Carbon or sediment filter No Removes chlorine, smell and dirt, not dissolved salts.

When is RO needed? If your TDS is above 500 ppm, RO is usually the right answer. If your TDS is already below 500 and your lab report shows no harmful items, you may not need an RO at all. In 2019, the National Green Tribunal told the government to restrict RO where TDS is below 500 and to push for at least 60% water recovery. A draft notification followed in 2020. Rules can change, so check the latest position before you buy.

TDS is the first question to ask about your water, never the last. A number tells you where to look. A lab report tells you what to do.


Section 08 · FAQs

Frequently Asked Questions About TDS in Water

QWhat is TDS in water?

TDS stands for Total Dissolved Solids. It is the total amount of minerals, salts and other substances dissolved in water, measured in ppm or mg/L. It includes harmless minerals like calcium and magnesium as well as harmful things like nitrate or metals. A TDS meter shows one combined number, not the list.

QWhat is a safe TDS level for drinking water in India?

Up to 500 ppm is the BIS acceptable limit. BIS allows up to 2,000 ppm only when no better source is available. For the best taste and healthy minerals, 50 to 300 ppm is ideal. Remember that TDS alone does not prove water is safe, since germs and some harmful chemicals do not show up in it.

QIs 500 TDS water safe to drink?

Yes, 500 ppm is right at the BIS acceptable limit, so it is considered fit to drink if other quality items are within limits. Some people find the taste slightly salty. If it is made of calcium and magnesium, it is usually fine. Get a lab test if you want to be sure.

QIs 1000 TDS water safe to drink?

It is above the BIS acceptable limit of 500 ppm and is not recommended for daily drinking. BIS allows up to 2,000 ppm only if there is no alternative source. At 1,000 ppm, the taste is often salty or bitter. An RO purifier can bring this down to a safe level.

QWhat is the ideal TDS for drinking water?

Most experts and the WHO taste guide point to 50 to 300 ppm as the sweet spot. WHO rates water under 300 ppm as excellent for taste. Under BIS, water up to 500 ppm is acceptable in India. Water below 50 ppm tastes flat and has very few minerals.

QIs low TDS water harmful?

Low TDS water is not poison, but very low levels (under 50 ppm) taste flat and carry few minerals. If you drink only RO water with 10 to 30 ppm TDS, make sure your diet has enough calcium and magnesium, or use a mineral cartridge. Do not run an RO if your source water is already low in TDS and safe.

QWhat TDS is good for cooking?

Water under 500 ppm works well for cooking. Very hard water can make dal and rajma take longer to soften, and may leave a film on tea. If your tap TDS is above 800 or 1,000 ppm, using treated water for cooking gives better taste and faster cooking.

QDoes boiling water reduce TDS?

No. Boiling does not reduce TDS. It can actually raise it because water turns to steam and the dissolved solids stay behind. Boiling is good for killing germs but does nothing for salts. Only RO, DM plants or distillation remove dissolved solids.

QDo UV or carbon filters reduce TDS?

No. UV only kills germs, and carbon or sediment filters remove dirt, chlorine and smell. None of them removes dissolved salts. If your TDS is high, you need RO or another desalting method.

QHow do I check TDS at home?

Use a digital TDS meter. Rinse a clean glass, fill it with water, dip the meter tip, tap away bubbles, and read the number after 10 seconds. Home meters are only a rough guide and can be off by 10% or more. For a business, a plant or a health concern, get a NABL lab test.

QWhat is the TDS limit for packaged drinking water and mineral water?

Packaged drinking water has a maximum TDS of 500 mg/L under IS 14543. Natural mineral water has a TDS range of 150 to 700 mg/L as per FSSAI guidance. Standards get revised, so plant owners should check the current version of the standard and FSSAI rules.

QWhat TDS is suitable for boilers, cooling towers and industrial processes?

It depends on the use. Low pressure boilers need soft feed water with hardness near zero and keep boiler water below about 3,500 ppm. High pressure boilers need DM water close to 0 ppm. Cooling towers can often use makeup water of 400 to 1,000 ppm. Medicine and DEF plants need near zero, with conductivity under about 1.3 and 0.5 µS/cm. Always follow your equipment maker or product standard.

QDo I need an RO if my TDS is below 500?

Usually not for TDS alone. If TDS is under 500 ppm and a lab test shows no harmful items, an RO may only strip out useful minerals and waste water. You may still need a UV or carbon filter for germs and chlorine. The National Green Tribunal also directed in 2019 that RO use be restricted where TDS is below 500, though you should check the latest rules.

QWhat is the difference between TDS and hardness?

TDS counts everything dissolved in water. Hardness counts only calcium and magnesium. Water can have high TDS with moderate hardness, or the reverse. BIS sets hardness at 200 mg/L acceptable and 600 mg/L permissible. Scale on taps and geysers is a hardness problem, and a water softener solves it, while it will not lower TDS.

This guide is for general information. Limits and standards change, and the right level depends on your use and local rules. For health concerns, talk to a doctor. For plant or industrial design, confirm limits with your equipment maker and a qualified water treatment engineer.

Know Your Number. Then Fix What Matters.

TDS is a simple number with big meaning. Too high, and your taste, your appliances and your factory equipment all suffer. Too low, and you may be paying to remove minerals you actually need.

The right fix starts with a proper water test. Then you choose the right treatment, whether that is an RO plant, a softener, a DM system or just a simple filter.

At Kaveri RO, we design water treatment for homes, factories, bottle plants and industry across India. Share your water report and your use, and we will tell you plainly what you need, and what you do not.

© 2026 Kaveri RO  ·  Water Treatment Solutions · Jaipur, Rajasthan  ·  kaveriro.com
Powered by Omni Themes